MODEL | DHS6248GB | |
Input Formation | L+N+PE | |
AC Input | 220/230/240VAC | |
Input Voltage Range | 90-280VAC±3VINormal Mode)185-264VAC±3V(UPS Mode) | |
Frequency | 50/60Hz(Adaptive) | |
Rated Power | 6200w | |
Dual Output Power | 6200W/6200W | |
Second Load Cut Off Voltage | 44V | |
Second Load Return Voltage | 52V | |
Output Voltage(Ac) | 208/220/230/240VAC±5% | |
Output Frequency | 50/60Hz±0.1% | |
Output Wave | Pure Sine Wave | |
Transfer Time(Adjustable) | 10ms for Computer Equipment,20ms for Household Equipment | |
Peak Power | 12400VA | |
Overload Ability | Batery Mode :21s@102%~110% load 10s@110%~130% load 3s @130%-150% load 400ms@>150% loac | |
Grid connected Operation |
Output voltage | 208/220/230/240VAC±5%(Feed-in Grid Voltage Range:195-253VAC) |
Grid Voltoge Range | 70-265VAC | |
Grid Frequency Range | 50/60Hz±0.1%(Feed-in Grid Frequency Range(49-51+1Hz/59-61+1Hz) | |
Output Current | 26.9A | |
Power Factor Range | >0.99 | |
Peak Efficiency(Battery Model) | >94% | |
Rated Voltage | 48VDC | |
Constant charging Voltage | 56.4Vdc | |
Float charging Voltage | 54VDC | |
PV Charging Method | MPPT | |
Max PV Input Power | 8500W | |
PV Input Voltage Range | 60~500VDC | |
MAX PV Input Voltage | 500VDC | |
MAX PV Input Current | 27A | |
MAX PV Charge Current | 120A | |
MAX AC Charge Current | 100A | |
MAX Charge Current | 120A | |
LCD | Can display operating mode/lood/input/output | |
RS232 | 5PIN/Pitch2.54mm,Baud Rate 2400 | |
Expansion Slot Communication Interface | Lithium Battery BMS Communication Card,WIFI 2x5PIN/Pitch2.54mm | |
Parallel Interface | Support Parallel | |
Operating Temperature | 0C-40℃ | |
Storage Temperature | 15℃~60℃ | |
Ork Altitude | No more than 1000m,if1000m<,Rate power will lower,MAX 4000m,Refer | |
Operating Environment Humidity | Non Condensing | |
Noise | <50dB | |
L*W*H(mm) | 495*312*125mm |